BT-AED02 China hospital medical portable aed machine defibrillator automatic external
It is a defibrillation device,which can meet your clinical needs from basic lift support to advanced cardiac life support.
5 Languages available:
English. Russian. Spanish. Chinese, Turkish
Itis a compact,durable, light weighted defibrillatorwhich integrated monitoring, manualdeirillation, AED and pacer (option).It is a professional biphasic.
defibrillator- monitor suitable for
hospitals and clinics,
with ECG monitoring paddles andCptional SpO2 (Nellcor, Meditech) :
NIBP, EtCO2 and PC Software
Technical specifications
Display
Screen Type: High-resolution display
. Screen Size: 7 inches (17.7 cm] diagonally
Sweep Speed: 25mm/sec
Information: Heart Rate, Lead/Pads, AlarmOn/Off, $pO2, AED
Functions and Prompis Alarm Selection andLimits, Delivered Energy.
SpO2 Module (Options):
Measurement Range: 30~ 100%, +2% between80%~90%, others t5%
Alarm Range: User set high limit and low limit.Alarm Accuracy: t10% within setting values.. Alarm time Accuracy: less than 12 sec.
Defibrillator
Waveform: Biphasic
. Charge Time: Less than 7 seconds with a new
fullyl charged battery.
Energy Display: Monitor display indicates bothselected and delivered energy.
Charge Prompt Type: Voice and visual prompts.Electrode Impedance Measurement Range: 0-250 ohms.
ECG Monitoring
. Patient Connection: 3-lead ECG cable, or 5-
lead ECG cable. paddles.
Lead Selec tion: Displayed on monitor, paddles,1,ll ll, AVR, AVL, AVF, v.
ECG Size: 0.25,0.5, 1, 1.5, 2, 4 cm/mV display onmonitor,
Heart Rate: 20-300BPM.
Heart Rate Alarm: On/Off displayed on monitor,user-selectable.
Smart Alarms: Beeper/voice prompts indicateshock able rhythm.
Battery
Type: Rechargeable, Ni-MH battery, 12v.
Operating Time: For anew, fully chargedbattery: 60 deibillatordischarges at maximum
energy, or 3 hours minimum of continuous ECGmonitoring Additional parameters will affectoperating time with different functions
EtCO2 (Options)
NIBP (Options)
Recorder
. Paper: 50mm thermal.
Speed: 12.5mm/sec, 25mm/sec, 50mm/sec.User- selectable 6-second delay.I
· Printing Method: High-resolution, thermal print head
Print-out Modes: Manual or automatic, user-configurable.
On/Off Control: Front panel and paddle.Automatic Function: 9-seconds recordinginitiated by alarm
activation or defilrllatoarcharge or deibillatordischarge.
AED Mode
AED Function: Auto analyze and charge x3 withprogrammable auto energy level selection,screen prompts, and voice prompts.
Shockable Rhythms: Ventricular ibll withamplitude >=200uV, ventricular tachycardia withrates >=140bpm, and QRS complex waveduration >=140ms.
. Charge Control: Control on device front panel,
press key on paddle.
Prompts: Voice and visual prompts.
Manual Mode
Energy Selection: Selectable at2, 5,7, 10, 20, 30,50. 70.100. 150, 200, 300. 360 joules.
· Synchronized Mode: Synchronizes efilillator
pulse to patient’s
. R-wave. “SYNC” message displayed on monitor